Inkqubo yokusebenza ekrelekrele; Kulula ukuyisebenzisa ngee-alamu ezibonakalayo nezesandi; Inkonzo/ujongano lolondolozo oluneenjongo ezininzi; Ukuprofayilisha: uxinaniso lwesodium kunye ne-UF curve.
I-W-T6008S iqinisekisa ukhuseleko kunye nokusebenza kakuhle ngexesha le-dialysis, inika unyango olukhululekile lwe-dialysis, olunokusetyenziswa: I-HDF ekwi-Intanethi, i-HD kunye ne-HF ekwi-Intanethi.
I-HDF ekwi-intanethi
Igumbi lokulinganisela ivolumu elivaliweyo elamkelweyo, ulawulo oluchanekileyo lokuphelelwa ngamanzi emzimbeni; Ukucoca ngesantya esiphantsi kwesitshixo esinye: kunokuseta isantya esiphantsi se-UF, ixesha lokusebenza le-UF eliphantsi, ukubuyela kwisantya esiqhelekileyo se-UF ngokuzenzekelayo emva kokwenziwa; ukuxhasa i-UF eyodwa, inokutshintsha ixesha elisetyenzisiweyo kunye nomthamo we-UF ngokusekelwe kwimfuno ngelixa i-UF yodwa.
Umsebenzi we-dialyzer priming one-key one-one-key
Ingamisela ixesha lokuyila, i-priming umthamo wokuphelelwa ngamanzi emzimbeni osebenzisa ngokufanelekileyo indlela yokusasazwa kunye ne-convection ukuphucula isiphumo sokuyila kwe-bloodlines kunye ne-dialyzer kunye nokuphucula ukwanela kwe-dialysis.
Inkqubo yokucoca nokubulala iintsholongwane ngokuzenzekelayo ekrelekrele
Ingathintela ngempumelelo ukufakwa kwe-calcium kunye neproteni kumjelo womatshini, akufuneki ukuba kusetyenziswe i-sodium hypochlorite ukususa iproteni ethintela ukwenzakala kwabasebenzi bezonyango ngexesha lokusetyenziswa kwe-sodium hypochlorite.
Umsebenzi wokukhupha amanzi obalulekileyo omnye
Umsebenzi wokukhupha amanzi oluncedo nosebenzayo, ukususa ngokuzenzekelayo ulwelo olungcolileyo olukwindawo yegazi kunye ne-dialyzer emva konyango lwe-dialysis, oluthintela ulwelo olungcolileyo ukuba lungachitheki emhlabeni xa kudilizwa umbhobho, lugcina indawo yonyango icocekile kwaye lunciphisa iindleko zolawulo kunye nezokuthutha inkunkuma yezonyango.
Inkqubo ye-alamu yesixhobo se-Hemodialysis ekrelekrele
Imbali ye-alamu kunye nokubulala iintsholongwane
Isikrini sokuchukumisa se-LCD se-intshi ezili-15
Uvavanyo lwe-Kt/V
Ukuseta ngokweeparamitha zeSodium kunye ne-UF ngokweemfuno zonyango lokwenyani lwezigulane, olulungele unyango olulungiselelwe wena, izigulane ziya kuziva zikhululekile ngakumbi ngexesha le-dialysis kwaye zinciphise ukwanda kweziphumo ezibi eziqhelekileyo.
| Ubungakanani nobunzima | |
| Ubungakanani | 380mmx400x1380mm (Ububanzi obuphezulu) |
| Ubunzima obupheleleyo bumalunga. | 88KG |
| Ubunzima obupheleleyo bumalunga. | malunga ne-100KG |
| Ubungakanani bephakheji malunga. | 650×690×1581mm (Ububanzi x Ububanzi) |
| Ukunikezwa Amandla | |
| I-AC220V, 50Hz/60Hz, 10A | |
| Amandla okufaka | 1500W |
| Ibhetri yokugcina idatha | imizuzu engama-30 |
| Imeko Yokusebenza | |
| Uxinzelelo lokufaka amanzi | 0.1Mpa~0.6Mpa, 15P.SI~60P.SI |
| Ubushushu bokufaka amanzi | 5℃~30℃ |
| Ubushushu bendawo yokusebenza | 10℃ ~ 30℃ kumswakama oqhelekileyo ≦70% |
| Ireyithi ye-UF | |
| Uluhlu lokuhamba | 0ml/h~4000ml/h |
| Umlinganiselo wesisombululo | 1ml |
| Uchaneko | ±30ml/h |
| Impompo yegazi kunye nempompo yokutshintsha | |
| Uluhlu lokuhamba kwegazi kwimpompo | 10ml/min~600ml/min (ububanzi: 8mm okanye 6mm) |
| Uluhlu lokuhamba kwepompo yokutshintsha | 10ml/min~300ml/min (ububanzi yi-8mm okanye i-6mm) |
| Umlinganiselo wesisombululo | 0.1ml |
| Uchaneko | ±10ml okanye i-10% yokufunda |
| Impompo yeHeparin | |
| Ubungakanani besirinji | 20, 30, 50ml |
| Uluhlu lokuhamba | 0ml/h~10ml/h |
| Umlinganiselo wesisombululo | 0.1ml |
| Uchaneko | ±5% |
| Inkqubo yokubeka iliso kunye nokuseta i-alamu | |
| Uxinzelelo lwemithambo yegazi | -180mmHg ~ +600mmHg, ±10mmHg |
| Uxinzelelo lwemithambo | -380mmHg ~ +400mmHg, ±10mmHg |
| I-TMP | -180mmHg ~ +600mmHg, ±20mmHg |
| Ubushushu be-Dialysate | uluhlu olucwangcisiweyo 34.0℃~39.0℃ |
| Ukuhamba kwe-Dialysate | Ngaphantsi kwe-800 ml/min (Iyalungiseka) |
| Uluhlu lokuhamba kokutshintshana | 0-28 L/H (kwi-HDF ekwi-intanethi) |
| Ukufunyanwa kokuvuza kwegazi | I-alamu ye-chromic yefoto xa umthamo othile we-erythrocyte uyi-0.32±0.02 okanye umthamo wokuvuza kwegazi ulingana okanye ungaphezulu kwe-1ml ngelitha nganye ye-dialysate. |
| Ukufunyanwa kwamaqamza | I-Ultrasonic, I-Alarm xa umthamo omnye webhamuza yomoya ungaphezulu kwe-200μl kwi-200ml/min yokuhamba kwegazi |
| Ukuqhuba | I-acoustic-optic |
| Ukubulala iintsholongwane/Ukucoca | |
| 1. Ukubulala iintsholongwane okushushu | |
| Ixesha: imizuzu engama-30; Ubushushu: malunga nama-80℃, ngesantya sokuhamba kwamanzi yi-500ml/min; | |
| 2. Ukubulala iintsholongwane ngamakhemikhali | |
| Ixesha: imizuzu engama-30, Ubushushu: malunga nama-36℃ ~ 50℃, ngesantya sokuhamba kwe-500ml/min; | |
| 3. Ukubulala iintsholongwane ngeekhemikhali ngobushushu | |
| Ixesha: imizuzu engama-45, Ubushushu: malunga nama-36℃ ~ 80℃, ngesantya sokuhamba kwe-50ml/min; | |
| 4. Hlamba | |
| Ixesha: imizuzu eli-10, Ubushushu: malunga nama-37℃, ngesantya sokuhamba kwe-800ml/min; | |
| Indawo yokugcina izinto | |
| Ubushushu bokugcina kufuneka bube phakathi kwe-5℃ ~ 40℃, kumswakama oqhelekileyo ≦80% | |
| Umsebenzi | |
| Iifilitha ze-HDF, i-BPM ekwi-intanethi, i-Bi-cart kunye nee-filters ze-endotoxin ezi-2 | |